Skip to main content

BioClean™ Suprene BSNS

Polychloroprene glove

To this glove in our product portfolio

Facts


Show comparison list
Surface cleanliness
Grip
Elongation
Endotoxin pollution
Ion-free
Cytostatics compatible
Chemical protection
sterile
textured
hand specific

Neoprene/polychloroprene

BioClean™ Suprene BSNS, Art.-No. 37309

Material: Neoprene/polychloroprene

Properties

  • 100% polychloroprene
  • sterile
  • packed in pairs in foil
  • hand specific

    Advantages

    • adequate surface cleanliness
    • very good form fit
    • very high elasticity
    • high permeation time with disinfectants
    • tested with cytostatics

    Application

    • sterile production / aseptic filling
    • for cleaning / disinfection with disinfectants and biocides
    • for the production of cytostatics
    • for heavy mechanical stress

    Product recommen­dation based on cleanroom classes

    Air cleanliness class EN ISO 14644-1
    particulate monitored areas

    123456789low dust

    Hygiene zones according to GMP
    microbiological monitored areas

    ABCDE

    PPE

    Personal protective equipment
    Regulation (EU) 2016/425

    Cat. ICat. IICat. IIInot aplicable

    A one-to-one classification of cleanroom gloves to a cleanroom class according to ISO 14644-1 is not possible. Recommendations can only be made based on cleanroom specific requirements, e.g. "abrasion resistance" or "particle emission". In the VDI guideline 2083 Part 9.2 the user can find additional information.

    Technical data

        Unit of measurementValueTest method
    Material   100% chloroprene
    rubber (CR)
       
    Perforation-free   AQL
    Piping stage
    1.5
    2
    EN 374-2:2015
    Tear resistance before ageing
    after accelerated ageing
    N min./typical n.s./n.s.
    n.s./≥ 9
    EN 455-2:2015
    EN 455-2:2015
    Extreme elongation before ageing
    after accelerated ageing
    % min.
    n.s
    n.s.
    EN 455-2:2015
    EN 455-2:2015
    Dimensions
    nominal single wall thickness
    fingertips
    palm
    cuff
    mm 0.18
    0.16
    0.12
     
    Length (+/- 10 mm)   mm typical 300 EN ISO 21420:2020
    Size/palm size
    nominal (+/- 5 mm)
    6
    6.5
    7
    7.5
    8
    8.5
    9
    mm 77
    83
    89
    95
    102
    108
    114
    EN ISO 21420:2020
    Size/Hand circumference
    nominal
    6
    6.5
    7
    7.5
    8
    8.5
    9
    mm n.s.
    EN ISO 21420:2020
    Extractable particles ≥ 0.5 µm number/cm2
    typical
    < 1,500 IEST-RP-CC005.4
    Sterilization   Sterility Assurance Level (SAL)
    for unopened/not damaged PE bag/
    MHD 5 years from date of manufacture
    10-6 ISO 11137-1:2006
    Endotoxins
    detected by LAL test, kinetic turbidimetric
      Endotoxin units
    (EU) per pair
    < 20 EN 455-3:2015
    Biocompatibility     n.s. Epicutaneous test according to Buehler +
    Primary Skin Irritation Tests
    Glove-related allergies
    sensitization of water-soluble
    natural latex proteins
    (type 1 allergy)
      µg/g ≤ 50 EN 455-3:2015
    Silicones, amides,
    Di-n-octyl phthalate (DNOP)
        not detectable IEST-RP-CC005.4
    FTIR measurement method
    Powder-free   µg/gloves compliant ISO 21171:2006
    Non volatile residues (NVR)   µg/g max. 30 IEST-RP-CC005.4
    Extractable ions

    NN = not detected
    NT = not tested




    Ions

    Ammonium (NH4+)
    Bromide (Br-)
    Calcium (Ca+)
    Chloride (ClO2-)
    Copper (Cu+)
    Fluoride (F-)
    Iron (Fe+)
    Lithium (Li+)
    Magnesium (Mg+)
    Nitrate (NO3-)
    Nitrite (NO2-)
    Phosphate (PO43-)
    Potassium (K+)
    Sodium (Na+)
    Sulphate (SO42-)
    Zinc (Zn+)
    µg/cm2
    specific
    n.s.
    n.s.
    n.s.
    n.s.
    n.s.
    n.s.
    n.s.
    n.s.
    n.s.
    n.s.
    n.s.
    n.s.
    n.s.
    n.s.
    n.s.
    n.s.
    µg/cm2
    typical
    0.004
    NN
    3.000
    0.899
    NT
    NN
    NT
    NN
    0.028
    3.841
    NN
    NN
    0.583
    0.410
    0.079
    0.062
    IEST-RP-CC005. 4

    ESD properties
    surface resistance
    contact resistance
    charge decay
    electrostatic properties (construction + material requirements)
        n.s
    EN 1149-1:2006
    EN 1149-2:1997
    EN 1149-3:2004
    EN 1149-5
    Food contact     suitable
    Regulation (EC) 1935/2004 +
    Regulation (EC) 2023/2006
    Permeation resistance
    of medical gloves for
    chemotherapeutic agents
        compliant ASTM D6978
    PU     100 pairs
    1 pair per PE flat bag
    in a sealed PE bag,
    10 pair/10 PE bags
    per sealed large bag
     
    Cardboard quantity     200 pairs
    20 big bags
     

    The manufacturer's technical data listed above are typical values at the time of publication. They are not specifications. All data are without guarantee, changes are possible without prior notice.

    To top