Skip to main content

KIMTECH™ G3 NxT™ Nitrile

Nitrile glove

To this glove in our product portfolio

Facts


Show comparison list
Surface cleanliness
Grip
Elongation
Endotoxin pollution
Ion-free
Cytostatics compatible
Chemical protection
sterile
textured
hand specific

Nitrile

Kimtech™ G3 NxT™ Nitrile, Art.-No. 3523

Material: Nitrile

Properties

  • 100% nitrile
  • powder-free, silicone-free
  • packed in bags
  • ambidextrous

Advantages

  • good surface cleanliness
  • high clearance of ions
  • conductive
  • high permeation time for chemicals
  • good mechanical resilience

Application

  • for high process requirements
  • for working with chemicals
  • for heavy mechanical stress

Product recommen­dation based on cleanroom classes

Air cleanliness class EN ISO 14644-1
particulate monitored areas

123456789low dust

Hygiene zones according to GMP
microbiological monitored areas

ABCDE

PPE

Personal protective equipment
Regulation (EU) 2016/425

Cat. ICat. IICat. IIInot aplicable

A one-to-one classification of cleanroom gloves to a cleanroom class according to ISO 14644-1 is not possible. Recommendations can only be made based on cleanroom specific requirements, e.g. "abrasion resistance" or "particle emission". In the VDI guideline 2083 Part 9.2 the user can find additional information.

Technical data

    Unit of measurementValueTest method
Material     100 % nitrile  
Perforation free1
AQL value as defined in ISO 2859-1
for attribute testing on samples
  AQL1 1.5 ASTM D5151
EN 374-2:2014
Tear resistance before ageing
after accelerated ageing
MPa, nominal 18
20
ASTM D412, ASTM D573
+ ASTM D3578
Extreme elongation before ageing
after accelerated ageing
%, nominal
600
600
ASTM D412, ASTM D573
+ ASTM D3578
Dimensions
nominal single wall thickness
middle finger
palm
cuff
mm 0.16
0.13
0.10
ASTM D3767, ASTM D6319
+ EN ISO 21420:2020
Length   mm
inch
305
12
 
Size/palm width X-Small
Small
Medium
Large
Large Plus
X-Large
mm 74
84
96
111
116
123
ASTM D3767, ASTM D6319
+ EN ISO 21420:2020
Biocompatibility     n.s. Primary Skin Irritation Tests +
Dermal Sensitization Test
according to ASTM F720-13
Extractable particles > 0.5 µm number/cm2 950 IEST-RP-CC005
Extractable substances
Ions

Ammonium (NH4+)
Bromide (Br-)
Calcium (Ca+)
Chloride (ClO-)
Copper (Cu+)
Fluoride (F-)
Iron (Fe+)
Lithium (Li+)
Magnesium (Mg2+)
Nitrate (NO3-)
Nitrite (NO2-)
Phosphate (PO43-)
Potassium (K+)
Sodium (Na+)
Sulphate (SO42-)
Zinc (Zn2+)
µg/g
specification
5
n.s.
50
35
n.s.
n.s.
n.s.
n.s.
5
20
n.s.
n.s.
5
5
10
7
µg/cm2
typical value
0.03
n.s.
0.33
0.23
n.s.
n.s.
n.s.
n.s.
0.03
0.13
n.s.
n.s.
0.03
0.03
0.07
0.04
IEST-RP-CC005
Non Volatile Residues (NVR)   mg/g n.s. IEST-RP-CC005.4
Endotoxins (maximum) Endotoxin units (EU) per pair n/a Kinetic turbidimetric
LAL test method
Electrostatic behaviour dissipative Ω 106 – 109 EN 1149-5:2003
Microorganisms risks     compliant
EN ISO 374-5:2016
PU     100 pieces
flat double bagged
 
Cardboard quantity     1,000 pieces
in a big bag
 

The manufacturer's technical data listed above are typical values at the time of publication. They are not specifications. All data are without guarantee, changes are possible without prior notice.

To top