Skip to main content

Isofield® NS400 

Nitrile glove

To this glove in our product portfolio

Facts


Show comparison list
Surface cleanliness
Grip
Elongation
Endotoxin pollution
Ion-free
Cytostatics compatible
Chemical protection
sterile
textured
hand specific

Nitrile

Isofield NS400, Art.-No. 37825

Material: Nitrile

Properties

  • 100% nitrile
  • disposable protective glove 
  • long non-slip protective cuff for the forearm
  • cleaned of production residues with deionised water
  • low endotoxin load
  • non sterile
  • ambidextrous
  • colour white
  • textured glove palm and finger inside
  • cuffs with beaded edge

Advantages

  • protective glove against hazardous chemicals (protection type B) for three different classes of substances such as inorganic bases, peroxides, aldehydes: K Sodium hydroxide 40%; P Hydrogen peroxide 30%; T Formaldehyde 37%
  • protective glove against micro-organisms such as viruses
  • long non-slip protective cuff against chemicals and microorganisms
  • Acceptable Quality Limit of the performance level 2 (1 up to 3)
  • meets the requirements and physical properties for medical gloves for single-use (EN 455-2:2015)
  • low extractable and leachable ionic loads
  • manufactured in an ISO cleanroom of cleanliness class 5 and certified by the National Environmental Balancing Bureau (NEBB)
  • double packed

Application

  • particulate controlled cleanrooms
  • laboratories working with certain hazardous chemicals and/or microorganisms

Product recommen­dation based on cleanroom classes

Air cleanliness class EN ISO 14644-1
particulate monitored areas

123456789low dust

Hygiene zones according to GMP
microbiological monitored areas

ABCDE

PPE

Personal protective equipment
Regulation (EU) 2016/425

Cat. ICat. IICat. IIInot aplicable

A one-to-one classification of cleanroom gloves to a cleanroom class according to ISO 14644-1 is not possible. Recommendations can only be made based on cleanroom specific requirements, e.g. "abrasion resistance" or "particle emission". In the VDI guideline 2083 Part 9.2 the user can find additional information.

Technical data

    Unit of measurementValueTest method
Material
    100% nitrile  
Perforation-free1
AQL value as defined in ISO 2859-1
for attribute testing on samples
  AQL1 1.5
Level 3
Inspection level G1
EN ISO 374-2:2019
Tear resistance before ageing
after accelerated ageing
N min./typical 6.0/n. s.
n. s./n. s.
EN 455-2:2015
Extreme elongation before ageing
after accelerated ageing
% min.
n. s.
n. s.
EN 455-2:2015
Dimensions
nominal single wall thickness
middle finger
glove palm
cuff
mm
± 0.02 mm
0.16
0.14
0.09
EN 455-2:2015
Length   mm min./typical 390/400 EN ISO 21420:2020
Size/palm width
nominal (+/- 5 mm)
Small
Medium
Large
X-Large
XX-Large
mm
+/- 0,02 mm
n. s. EN ISO 21420:2020
EN 455-2:2015
Permeation performance against chemicals     Type B EN ISO 374-1:2016 + A1:2018
Protection against microbiological pathogens
viruses or bacteria or fungi
    passed
viruses
EN ISO 374-5:2016
Extractable particles ≥ 0.5 µm nominal
number/cm2
1,800 IEST-RP-CC005.4
Extractable substances
Ions

Ammonium (NH4+)
Bromide (Br-)
Calcium (Ca+)
Chloride (ClO2-)
Copper (Cu+)
Fluoride (F-)
Iron (Fe+)
Lithium (Li+)
Magnesium (Mg+)
Nitrate (NO3-)
Nitrite (NO2-)
Phosphate (PO43-)
Potassium (K+)
Sodium (Na+)
Sulphate (SO42-)
Zinc (Zn+)
µm/cm2
Spezifikation
n. s.
n. s.
n. s.
n. s.
n. s.
n. s.
n. s.
n. s.
n. s.
n. s.
n. s.
n. s.
n. s.
n. s.
n. s.
n. s.
µm/cm2
Typical value
0.020
n. d.
0.432
0.031
n. s.
n. d.
n. s.
n. s.
n. d.
0,500
n. s.
0.062
0.064
0.050
0012
n. d.
IEST-RP-CC005.4
Endotoxins
detected by LAL-test, kinetic turbidimetric
  Endotoxin units
(EU) per pair
n. s. EN 455-3:2015
Silicones, amides, Di-n-octyl phthalate (DNOP)
    n. s. IEST-RP-CC005.4
FTIR test procedure
Powder residue values   mg/gloves
typical (max. 2 mg)
powder-free
< 2 mg
ASTM D6124
Biocompatibility     n. s. ISO 10993-10:2010
Skin sensitization     passed ISO 10993-10:2021
Non volatile residues (NVR)   mg/g n. s. IEST-RP-CC005.4
ESD properties
surface resistance
contact resistance
charge decay
electrostatic properties (design + material requirements)
    n. s.

EN 1149-1:2006
EN 1149-2:1997
EN 1149-3:2004
EN 1149-5
Permeation resistance
of medical gloves for
chemotherapeutics
    not applicable ASTM D6978-05(2019)
Shelf life from date of manufacture     three (3) years when stored properly
PU     1,000 pieces
100 pcs per sealed inner PE bag
one inner PE bag per sealed outer PE bag
10 outer PE bags per lined carton
 
      n. s. = not specified
n. d. = not detected
 

The manufacturer's technical data listed above are typical values at the time of publication. They are not specifications. All data are without guarantee, changes are possible without prior notice.

To top