Skip to main content

SHIELDskin™
ORANGE NITRILE™ 300

Nitrile-polychloroprene glove

To this glove in our product portfolio

Facts


Show comparison list
Surface cleanliness
Grip
Elongation
Endotoxin pollution
Ion-free
Cytostatics compatible
Chemical protection
sterile
textured
hand specific

Nitrile-polychloroprene mixture

SHIELDskin™ ORANGE NITRILE™ 300, Art.-No. 3841

Material: Nitrile-polychloroprene mixture

Properties

  • nitrile / polychloroprene mixture
  • powder-free
  • packed in boxes
  • ambidextrous

Advantages

  • adequate surface cleanliness
  • high permeation time for chemicals
  • good grip
  • tested with cytostatics
  • 30 cm long

Application

  • for laboratory requirements
  • for working with chemicals
  • for the production of cytostatics

Product recommen­dation based on cleanroom classes

Air cleanliness class EN ISO 14644-1
particulate monitored areas

123456789low dust

Hygiene zones according to GMP
microbiological monitored areas

ABCDE

PPE

Personal protective equipment
Regulation (EU) 2016/425

Cat. ICat. IICat. IIInot aplicable

A one-to-one classification of cleanroom gloves to a cleanroom class according to ISO 14644-1 is not possible. Recommendations can only be made based on cleanroom specific requirements, e.g. "abrasion resistance" or "particle emission". In the VDI guideline 2083 Part 9.2 the user can find additional information.

Technical data

    Unit of measurementValueTest method
Material
Outer layer/inner layer
    nitrile/polychloroprene
orange/white
 
Perforation-free1
AQL value as defined in ISO 2859-1
for attribute testing on samples
  AQL1 0.25 Level 3 ISO 374-2:2019
EN 455-1.2020
Tear resistance before ageing
after accelerated ageing
N spec/typical ≥ 6.0/7.0
≥ 6.0/8.0
EN 455-2:2015 + ASTM D412-15a
ASTM D573-04(2015)
Extreme elongation before ageing
after accelerated ageing
% spec
≥ 500
≥ 400
EN 455-2:2015 + ASTM D412-15a
ASTM D573-04(2015)
Dimensions
nominal single wall thickness
middle finger
hand surface
cuff
mm (+/- 3 mm) 0.17
0.14
0.10
ASTM D3767-03(2014)
Length   mm min/typical ≥ 290/300 EN 455-2:2015
Size/palm width
nominal (+/- 5 mm)
XS / 6
S / 7
M / 8
L / 9
XL / 10
XXL / 11
mm ≤ 80
85
95
105
115
120
EN 455-2:2015
Size/Hand circumference
nominal
XS / 6
S / 7
M / 8
L / 9
XL / 10
mm
mm 152
178
203
229
254
279
EN 455-2:2015
Biocompatibility     passed Epicutaneous test according to Buehler +
Primary Skin Irritation Tests
Powder residue values   mg/gloves
typical (max.)
powder-free
≤ 1.0 (max. 2.0)
ISO 21171:2006
Chemical allergens     passed High-Performance Liquid Chromatography for quantitative
analysis + by aqueous phosphate solution extraction
Vulcanisation accelerators     free reduces the risk of contact dermatitis
(type IV allergy/chemical allergy)
Extractable particles ≥ 0.5 µm spec
typical
number/cm2
n.s.
n.s.
IEST-RP-CC005.4
Extractable substances
Ions

Ammonium (NH4+)
Bromide (Br-)
Calcium (Ca+)
Chloride (ClO2-)
Copper (Cu+)
Fluoride (F-)
Iron (Fe+)
Lithium (Li+)
Magnesium (Mg+)
Nitrate (NO3-)
Nitrite (NO2-)
Phosphate (PO43-)
Potassium (K+)
Sodium (Na+)
Sulphate (SO42-)
Zinc (Zn+)
µm/cm2
specification
n.s.
n.s.
n.s.
n.s.
n.s.
n.s.
n.s.
n.s.
n.s.
n.s.
n.s.
n.s.
n.s.
n.s.
n.s.
n.s.
µm/cm2
typical value
n.s.
n.s.
n.s.
n.s.
n.s.
n.s.
n.s.
n.s.
n.s.
n.s.
n.s.
n.s.
n.s.
n.s.
n.s.
n.s.
IEST-RP-CC005.4
Non Volatile Residues (NVR)   mg/g n.s. IEST-RP-CC005.4
Endotoxins (maximum)   Endotoxin units (EU)
per pair
n.s. Kinetic turbidimetric
LAL test method
ESD properties
surface resistance
contact resistance
charge decay
electrostatic properties
(design + material requirements)
    tested
EN 1149-1:2006
EN 1149-2:1997
EN 1149-3:2004
EN 1149-5
Permeation resistance
of medical gloves for
chemotherapeutics
    tested ASTM D6978-05(2019)
PU     50 pieces
flat packed in carton
dispenser (inner box)
 
Carton quantity     500 pieces
10 carton dispensers
 

The manufacturer's technical data listed above are typical values at the time of publication. They are not specifications. All data are without guarantee, changes are possible without prior notice.