Skip to main content

Series 300 S

Polyester-cellulose wipe

Back to our sterile dry wipes

The validated sterile version of the series 300, a polyester cellulose non-woven wipe, is versatile, both in microbiological controlled zones and in purely particle controlled areas. Despite the non-woven construction, the wipe is characterised by a certain abrasion and tear resistance (even when damp).
The cloth of the wipes combines the different strengths of cellulose (➜ absorbency) and polyester fibre (➜ abrasion resistance) and is therefore also a happy medium in terms of costs. The hydro-entangled non-woven fabric is, in direct comparison to the series 302, not quite as low in particles and fibres.

Facts

Particle emission (dry)
Particle emission (wet)
Abrasion resistance
Wet cleaning
Dry cleaning
Chemical permanence
Electrostatic behaviour
Softness
Sealed edges
decontaminated
sterile

Polyester-cellulose

Series 300 S

Non-woven, 45% PES / 55% CEL, hydroentangled, validated sterile

-
-
-

Properties

  • 45% polyester / 55% cellulose
  • hydroentangled non-woven fabric
  • validated sterile
  • low particle and fibre emission
  • relatively abrasion resistant
  • special twill-textured surface
  • good absorptive capacity
  • double bag packing

Advantages

  • good chemical compatibility with different solvents and cleaning agents  
  • multipurpose
  • cost effective

Applications

  • all-purpose wipe
  • absorption of liquids and spills
  • suitable for cleaning tools
  • workplace cleaning – especially for smooth surfaces

Product recommen­dation based on cleanroom classes


123456789low dust


ABCDE

Of course, cleanroom wipes used in ISO 5 can also be used in ISO 9, but in this case the economic efficiency and usefulness should be considered.

A 1 to 1 allocation of cleanroom wipes to an air cleanliness class according to ISO 14644-1 is not possible. Recommendations can only be made on the basis of special properties relevant from a cleanroom technical point of view, such as "abrasion resistance" or "particle emission". Users can find further information on this in VDI Guideline 2083 Part 9.2.

Technical data

Properties   Unit of measurementValueTest method
Material     45% PES / 55% CEL  
Edge processing     cold cut  
Mass per unit area   g/m2 68  
Thickness   mm 0.30  
Absorptive capacity
(Ai) intrinsic
(Ae) extrinsic
 
ml/g
ml/m2

6.7
396
IEST-RP-CC004.3
NVR
Non-volatile residues
IPA based
DI water based
g/m2
g/m2
0.028
0.038
IEST-RP-CC004.3
Particulate residues 0.5 – ≤ 5.0 µm
> 5.0 – ≤ 100 µm
x 106/m2
x 106/m2
140
9.9
IEST-RP-CC004.3
Section 6.1.3
Biaxial Shake Test

Fibre residues > 100 µm fibres/m2 154,778 IEST-RP-CC004.3
Section 6.2.2.2
Ionic residues Sodium (Na+)
Chloride (ClO2-)
ppm
ppm
70
42
IEST-RP-CC004.3
Section 7.2.2.1
Sterilisation validated sterile Sterility Assurance Level
(SAL)
10-6 AAMI / ISO 11137
Organic contaminants silicone oil
amides
D-n-octylphthalate (DOP)
  n. s.
n. s.
n. s.
by FTIR spectrometer
Fourier transform infrared spectrometer
  DimensionsPU per bagArt. No.  
  4" x 4"
9" x 9"
12" x 12"
18" x 18"
on request
150 pieces (6 x 25)
150 pieces (6 x 25)
75 pieces (3 x 25)
57300 0404
57300 0909
57300 1212
57300 1818
 
      n. s. = not specified
n. d. = not detectable
 

Note

The manufacturer's technical data listed above are typical values at the time of publication. They are not specifications. All data are without guarantee, changes are possible without prior notice.
Due to different test methods depending on the respective manufacturers and test laboratories, most of the given values cannot be compared one-to-one with those of other manufacturers/wipes.
Independent tests can be commissioned on request.

To top