Skip to main content

PROSAT® Sterile Wipes

Saturated wipe

Back to our saturated wipes

The very clean 100% polypropylene wipes PROSAT® Wipes, saturated with 70% IPA / 30% DI water (USP grade), consist of a meltblown non-woven fabric. They are available in a sterile or non-sterile version. The wipes are free of additives of any kind. Packed in an easy-to-open and reclosable pouch, the wipes can be easily dispensed and their shelf life extended.

 

Facts

Particle emission (dry)
Particle emission (wet)
Abrasion resistance
Wet cleaning
Dry cleaning
Chemical permanence
Electrostatic behaviour
Softness
Sealed edges
decontaminated
sterile

Saturated wipes

PROSAT® Sterile Wipes

Non-woven, 100% PP, with 70% IPA / 30% DI water, validated sterile

-
-
-
-

Properties

  • 100% polypropylene
  • meltblown non-woven fabric
  • presaturated with 70% IPA / 30% DI water (USP grade)
  • reclosable PE pouch 
  • packed in an outer bag
  • validated sterile (SAL of 10-6), triple bag packaging

Advantages

  • reduced level of volatile organic compounds (VOC)
  • fast and efficient cleaning
  • reduces the storage of cleaning agents
  • easier to transport, store and use
  • even application of the cleaning solution

Applications

  • wiping of objects before the airlock procedure
  • for quick and practical surface cleaning of equipment and parts 
  • wet cleaning of scratch-sensitive surfaces to specifically remove chemical residues

Product recommen­dation based on cleanroom classes


123456789low dust


ABCDE

Of course, cleanroom wipes used in ISO 5 can also be used in ISO 9, but in this case the economic efficiency and usefulness should be considered.

A 1 to 1 allocation of cleanroom wipes to an air cleanliness class according to ISO 14644-1 is not possible. Recommendations can only be made on the basis of special properties relevant from a cleanroom technical point of view, such as "abrasion resistance" or "particle emission". Users can find further information on this in VDI Guideline 2083 Part 9.2.

Technical data

Properties   Unit of measurementValueTest method
Material (fabric)     100% polypropylene (PP)  
Saturation solution     70% IPA (USP grade) /
30% DI water
 
Edge processing     cut  
Mass per unit area   g/m2 36  
Thickness   mm n.s.  
NVR
Non-volatile residues
IPA based
DI-water based
g/m²
g/m²
0.07
0.01
IEST-RP-CC004.3, Sec. 7.1.2
IEST-RP-CC004.3, Sec. 7.1.2
Particle residues ≥ 0.5 µm x 106/m2 5.8 IEST-RP-CC004.2, Sec. 5.1
Fiber residues > 100 µm x 103/m2 6.3 IEST-RP-CC004.2, Sec. 5.2
Ionic residues Sodium (Na+)
Chloride (ClO2-)
ppm
ppm
3
5
IEST-RP-CC004.3, Sec. 7.2.2
IEST-RP-CC004.3, Sec. 7.2.2
Sterilisation Electron Beam Irradiadion (EBI) SAL (10-6) yes AAMI Guidelines
Association for the Advancement of Medical Instrumentation
  DimensionsPieces per pouch -
amount of saturation solution
PU per cardboardArt. no.
  9" x 11"
(~ 23 x 28 cm)
30 pcs./pouch - 310 ml 1,440 pieces 59801

Note

The manufacturer's technical data listed above are typical values at the time of publication. They are not specifications. All data are without guarantee, changes are possible without prior notice.
Due to different test methods depending on the respective manufacturers and test laboratories, most of the given values cannot be compared one-to-one with those of other manufacturers/wipes.
Independent tests can be commissioned on request.

To top